<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Portfolio Archive - Cesamo</title>
	<atom:link href="https://cesamo.fr/en/portfolio_page/feed/" rel="self" type="application/rss+xml" />
	<link>https://cesamo.fr/en/portfolio_page/</link>
	<description>Un site utilisant WordPress</description>
	<lastBuildDate>Thu, 26 Nov 2020 12:55:00 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>
	<item>
		<title>Leica M 125</title>
		<link>https://cesamo.fr/en/portfolio_page/leica-m-125-en/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=leica-m-125-en</link>
					<comments>https://cesamo.fr/en/portfolio_page/leica-m-125-en/#respond</comments>
		
		<dc:creator><![CDATA[Marguerite]]></dc:creator>
		<pubDate>Mon, 19 Oct 2020 10:29:47 +0000</pubDate>
				<guid isPermaLink="false">http://cesamo.fr/?post_type=portfolio_page&#038;p=418</guid>

					<description><![CDATA[<p>Leica M 125 stereo microscope with polarized light (possibility to take pictures) Date of purchase: November 2011</p>
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/leica-m-125-en/">Leica M 125</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 style="text-align: justify;"></h3>
<h3 style="text-align: justify;">Leica M 125</h3>
<p style="text-align: justify;"><img fetchpriority="high" decoding="async" class="alignnone wp-image-187 size-full" src="http://cesamo.fr/wp-content/uploads/2020/10/equipement-cesamo-diffraction-rx-microscope-leika-cesamo.jpg" alt="" width="1920" height="1280" srcset="https://cesamo.fr/wp-content/uploads/2020/10/equipement-cesamo-diffraction-rx-microscope-leika-cesamo.jpg 1920w, https://cesamo.fr/wp-content/uploads/2020/10/equipement-cesamo-diffraction-rx-microscope-leika-cesamo-300x200.jpg 300w, https://cesamo.fr/wp-content/uploads/2020/10/equipement-cesamo-diffraction-rx-microscope-leika-cesamo-1024x683.jpg 1024w, https://cesamo.fr/wp-content/uploads/2020/10/equipement-cesamo-diffraction-rx-microscope-leika-cesamo-768x512.jpg 768w, https://cesamo.fr/wp-content/uploads/2020/10/equipement-cesamo-diffraction-rx-microscope-leika-cesamo-1536x1024.jpg 1536w, https://cesamo.fr/wp-content/uploads/2020/10/equipement-cesamo-diffraction-rx-microscope-leika-cesamo-700x467.jpg 700w" sizes="(max-width: 1920px) 100vw, 1920px" /></p>
<h4 style="text-align: justify;"></h4>
<ul style="text-align: justify;">
<li style="list-style-type: none;">
<ul style="text-align: justify;">
<li>stereo microscope with polarized light (possibility to take pictures)
<p><em>Date of purchase: November 2011</em></li>
</ul>
</li>
</ul>
<h3 style="text-align: justify;"></h3>
<p style="text-align: justify;">
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/leica-m-125-en/">Leica M 125</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://cesamo.fr/en/portfolio_page/leica-m-125-en/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Bruker Kappa APEX II DUO</title>
		<link>https://cesamo.fr/en/portfolio_page/bruker-kappa-apex-ii-duo-en/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=bruker-kappa-apex-ii-duo-en</link>
					<comments>https://cesamo.fr/en/portfolio_page/bruker-kappa-apex-ii-duo-en/#respond</comments>
		
		<dc:creator><![CDATA[Marguerite]]></dc:creator>
		<pubDate>Mon, 19 Oct 2020 10:25:50 +0000</pubDate>
				<guid isPermaLink="false">http://cesamo.fr/?post_type=portfolio_page&#038;p=416</guid>

					<description><![CDATA[<p>Bruker Kappa APEX II DUO four-circle diffractometer (Kappa geometry) dual source (an IμS type Cu / 45kV anticathode microsource and an IμS Mo / 50kV anticathode type microsource). The two X-ray sources make it possible to adapt measurements to sample. 2-dimensional CCD detector APEX II...</p>
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/bruker-kappa-apex-ii-duo-en/">Bruker Kappa APEX II DUO</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 style="text-align: justify;"></h3>
<h3 style="text-align: justify;">Bruker Kappa APEX II DUO</h3>
<p style="text-align: justify;"><img decoding="async" class="alignnone wp-image-184 size-full" src="http://cesamo.fr/wp-content/uploads/2020/10/equipement-cesamo-diffraction-rx-bruker-kappa-cesamo.jpg" alt="" width="1920" height="1280" srcset="https://cesamo.fr/wp-content/uploads/2020/10/equipement-cesamo-diffraction-rx-bruker-kappa-cesamo.jpg 1920w, https://cesamo.fr/wp-content/uploads/2020/10/equipement-cesamo-diffraction-rx-bruker-kappa-cesamo-300x200.jpg 300w, https://cesamo.fr/wp-content/uploads/2020/10/equipement-cesamo-diffraction-rx-bruker-kappa-cesamo-1024x683.jpg 1024w, https://cesamo.fr/wp-content/uploads/2020/10/equipement-cesamo-diffraction-rx-bruker-kappa-cesamo-768x512.jpg 768w, https://cesamo.fr/wp-content/uploads/2020/10/equipement-cesamo-diffraction-rx-bruker-kappa-cesamo-1536x1024.jpg 1536w, https://cesamo.fr/wp-content/uploads/2020/10/equipement-cesamo-diffraction-rx-bruker-kappa-cesamo-700x467.jpg 700w" sizes="(max-width: 1920px) 100vw, 1920px" /></p>
<h4 style="text-align: justify;"></h4>
<ul>
<li>four-circle diffractometer (Kappa geometry)</li>
<li>dual source (an IμS type Cu / 45kV anticathode microsource and an IμS Mo / 50kV anticathode type microsource).</li>
</ul>
<p>The two X-ray sources make it possible to adapt measurements to sample.</p>
<ul>
<li>2-dimensional CCD detector APEX II</li>
<li>a low temperature liquid nitrogen measuring device Cryostream 700 Oxford Cryosystems allowing measurements in a range varying from 80K to 400K.</li>
</ul>
<p style="text-align: justify;"><em>Date of purchase: November 2011</em></p>
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/bruker-kappa-apex-ii-duo-en/">Bruker Kappa APEX II DUO</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://cesamo.fr/en/portfolio_page/bruker-kappa-apex-ii-duo-en/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>GCMS-ISQ &#8211; Thermo</title>
		<link>https://cesamo.fr/en/portfolio_page/gcms-isq-thermo-en/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=gcms-isq-thermo-en</link>
		
		<dc:creator><![CDATA[Marguerite]]></dc:creator>
		<pubDate>Tue, 13 Oct 2020 12:00:50 +0000</pubDate>
				<guid isPermaLink="false">http://cesamo.fr/?post_type=portfolio_page&#038;p=463</guid>

					<description><![CDATA[<p>GCMS-ISQ &#8211; Thermo Location : 2nd floor  East, room 2S24 The CESAMO platform is equipped with two GC/MS ISQ (ThermoFisher) mass spectrometer coupled to a gas chromatography apparatus. They are equipped with a quadrupole analyzer. There are several possibilities for introducing the sample : either by standard...</p>
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/gcms-isq-thermo-en/">GCMS-ISQ &#8211; Thermo</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 style="text-align: justify;"></h3>
<h3 style="text-align: justify;">GCMS-ISQ &#8211; Thermo</h3>
<p style="text-align: justify;"><img decoding="async" class="alignnone wp-image-143 size-full" src="http://cesamo.fr/wp-content/uploads/2020/10/gcms-isq-thermo-spectrometrie-de-masse-1.jpg" alt="" width="1920" height="1280" srcset="https://cesamo.fr/wp-content/uploads/2020/10/gcms-isq-thermo-spectrometrie-de-masse-1.jpg 1920w, https://cesamo.fr/wp-content/uploads/2020/10/gcms-isq-thermo-spectrometrie-de-masse-1-300x200.jpg 300w, https://cesamo.fr/wp-content/uploads/2020/10/gcms-isq-thermo-spectrometrie-de-masse-1-1024x683.jpg 1024w, https://cesamo.fr/wp-content/uploads/2020/10/gcms-isq-thermo-spectrometrie-de-masse-1-768x512.jpg 768w, https://cesamo.fr/wp-content/uploads/2020/10/gcms-isq-thermo-spectrometrie-de-masse-1-1536x1024.jpg 1536w, https://cesamo.fr/wp-content/uploads/2020/10/gcms-isq-thermo-spectrometrie-de-masse-1-700x467.jpg 700w" sizes="(max-width: 1920px) 100vw, 1920px" /></p>
<h3 style="text-align: justify;"></h3>
<p>Location : 2<sup>nd</sup> floor  East, room 2S24</p>
<p style="text-align: justify;">The CESAMO platform is equipped with two GC/MS ISQ (ThermoFisher) mass spectrometer coupled to a gas chromatography apparatus. They are equipped with a quadrupole analyzer. There are several possibilities for introducing the sample : either by standard gas chromatography, or in &#8220;headspace&#8221; mode which enables volatile compounds to be analyzed, or in pyrolysis mode which enables the study of macromolecular compounds.  The range of analyzable masses extends from 1 to 1000 m/z. The different sources of ionization are EI (Electronic Ionization), PCI (Positive Chemical Ionization) and NCI (Negative Chemical Ionization).</p>
<p> This instrument is used :</p>
<ul>
<li style="text-align: justify;">For the qualitative and quantitative analysis of mixtures or pure non-thermolabile products with masses less than 1000.</li>
<li style="text-align: justify;">For the characterization of polymers by pyrolysis.</li>
</ul>
<p style="text-align: justify;">
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/gcms-isq-thermo-en/">GCMS-ISQ &#8211; Thermo</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Accutof &#8211; JEOL</title>
		<link>https://cesamo.fr/en/portfolio_page/accutof-jeol-en/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=accutof-jeol-en</link>
		
		<dc:creator><![CDATA[Marguerite]]></dc:creator>
		<pubDate>Tue, 13 Oct 2020 11:59:04 +0000</pubDate>
				<guid isPermaLink="false">http://cesamo.fr/?post_type=portfolio_page&#038;p=462</guid>

					<description><![CDATA[<p>Accutof &#8211; JEOL Location : 2nd floor  East, room 2N24 The AccuToF Mass Spectrometer (Jeol) is a GC-TOF type mass spectrometer acquired in 2011. Its resolving power is greater than 6000 at 617 Da mass. The range of analyzable masses is between 0 and 4000 m/z. The...</p>
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/accutof-jeol-en/">Accutof &#8211; JEOL</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 style="text-align: justify;"></h3>
<h3 style="text-align: justify;">Accutof &#8211; JEOL</h3>
<p style="text-align: justify;"><img loading="lazy" decoding="async" class="alignnone wp-image-141 size-full" src="http://cesamo.fr/wp-content/uploads/2020/10/accutof-jeol-spectrometrie-de-masse-cesamo-bordeaux.jpg" alt="" width="1920" height="1280" srcset="https://cesamo.fr/wp-content/uploads/2020/10/accutof-jeol-spectrometrie-de-masse-cesamo-bordeaux.jpg 1920w, https://cesamo.fr/wp-content/uploads/2020/10/accutof-jeol-spectrometrie-de-masse-cesamo-bordeaux-300x200.jpg 300w, https://cesamo.fr/wp-content/uploads/2020/10/accutof-jeol-spectrometrie-de-masse-cesamo-bordeaux-1024x683.jpg 1024w, https://cesamo.fr/wp-content/uploads/2020/10/accutof-jeol-spectrometrie-de-masse-cesamo-bordeaux-768x512.jpg 768w, https://cesamo.fr/wp-content/uploads/2020/10/accutof-jeol-spectrometrie-de-masse-cesamo-bordeaux-1536x1024.jpg 1536w, https://cesamo.fr/wp-content/uploads/2020/10/accutof-jeol-spectrometrie-de-masse-cesamo-bordeaux-700x467.jpg 700w" sizes="(max-width: 1920px) 100vw, 1920px" /></p>
<h3 style="text-align: justify;"></h3>
<p>Location : 2<sup>nd</sup> floor  East, room 2N24</p>
<p style="text-align: justify;">The AccuToF Mass Spectrometer (Jeol) is a GC-TOF type mass spectrometer acquired in 2011. Its resolving power is greater than 6000 at 617 Da mass. The range of analyzable masses is between 0 and 4000 m/z. The measurement accuracy is less than 5 ppm in external calibration. The different possible sources are: EI (Electronic Ionization), CI (Chemical Ionization) and FI / FD (Ionization / Field Desorption). It can work in coupling with a gas chromatograph or in direct introduction mode.</p>
<p>This instrument is used :</p>
<ul>
<li style="text-align: justify;">For high-resolution mass measurements (determination of molecular formulas) on pure or mixed products (high-resolution GC / MS coupling).</li>
<li style="text-align: justify;">For the analysis of non-polar compounds in high resolution</li>
</ul>
<p style="text-align: justify;">
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/accutof-jeol-en/">Accutof &#8211; JEOL</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Autoflex Bruker</title>
		<link>https://cesamo.fr/en/portfolio_page/autoflex-bruker-2/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=autoflex-bruker-2</link>
		
		<dc:creator><![CDATA[Marguerite]]></dc:creator>
		<pubDate>Tue, 13 Oct 2020 11:57:14 +0000</pubDate>
				<guid isPermaLink="false">http://cesamo.fr/?post_type=portfolio_page&#038;p=461</guid>

					<description><![CDATA[<p>Autoflex Bruker Location : 2nd floor  East, room 2N24 The Autoflex Mass Spectrometer is a MALDI-type mass spectrometer equipped with a ToF analyzer, acquired in 2019. Its resolving power is 26,000. The range of masses that can be studied extends from 200 to 350,000 m/z. The laser...</p>
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/autoflex-bruker-2/">Autoflex Bruker</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 style="text-align: justify;"></h3>
<h3 style="text-align: justify;">Autoflex Bruker</h3>
<p style="text-align: justify;"><img loading="lazy" decoding="async" class="alignnone wp-image-139 size-full" src="http://cesamo.fr/wp-content/uploads/2020/10/autoflex-bruker-cesamo-universite-bordeaux.jpg" alt="" width="1920" height="1280" srcset="https://cesamo.fr/wp-content/uploads/2020/10/autoflex-bruker-cesamo-universite-bordeaux.jpg 1920w, https://cesamo.fr/wp-content/uploads/2020/10/autoflex-bruker-cesamo-universite-bordeaux-300x200.jpg 300w, https://cesamo.fr/wp-content/uploads/2020/10/autoflex-bruker-cesamo-universite-bordeaux-1024x683.jpg 1024w, https://cesamo.fr/wp-content/uploads/2020/10/autoflex-bruker-cesamo-universite-bordeaux-768x512.jpg 768w, https://cesamo.fr/wp-content/uploads/2020/10/autoflex-bruker-cesamo-universite-bordeaux-1536x1024.jpg 1536w, https://cesamo.fr/wp-content/uploads/2020/10/autoflex-bruker-cesamo-universite-bordeaux-700x467.jpg 700w" sizes="(max-width: 1920px) 100vw, 1920px" /></p>
<h3 style="text-align: justify;"></h3>
<p>Location : 2<sup>nd</sup> floor  East, room 2N24</p>
<p style="text-align: justify;">The Autoflex Mass Spectrometer is a MALDI-type mass spectrometer equipped with a ToF analyzer, acquired in 2019. Its resolving power is 26,000. The range of masses that can be studied extends from 200 to 350,000 m/z. The laser used is of the Smartbeam type. This device is also equipped with a FAST system particularly suitable for the study of peptides, for example :</p>
<ul>
<li style="text-align: justify;">This instrument can be used for the analysis of molecules of high masses: polymers and proteins.</li>
<li style="text-align: justify;">In the case of the study of polymers, it allows the determination of chain ends (for masses less than 20,000), confirmation of the monomer unit, calculation of the molar mass and of the polymolecularity</li>
</ul>
<p style="text-align: justify;">
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/autoflex-bruker-2/">Autoflex Bruker</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Qexactive &#8211; Thermo</title>
		<link>https://cesamo.fr/en/portfolio_page/qexactive-thermo-en/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=qexactive-thermo-en</link>
		
		<dc:creator><![CDATA[Marguerite]]></dc:creator>
		<pubDate>Tue, 13 Oct 2020 11:54:01 +0000</pubDate>
				<guid isPermaLink="false">http://cesamo.fr/?post_type=portfolio_page&#038;p=460</guid>

					<description><![CDATA[<p>Qexactive &#8211; Thermo Location : 2nd floor  East, room 2N24 It is an orbitrap-type mass spectrometer that was acquired in 2018. It has a resolving power of 140,000 FWHM (Full Width at Half Maximum). The range of masses that can be analyzed with this type of device...</p>
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/qexactive-thermo-en/">Qexactive &#8211; Thermo</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 style="text-align: justify;"></h3>
<h3 style="text-align: justify;">Qexactive &#8211; Thermo</h3>
<p style="text-align: justify;"><img loading="lazy" decoding="async" class="alignnone wp-image-135 size-full" src="http://cesamo.fr/wp-content/uploads/2020/10/qexative-thermo-spectrometrie-de-masse-cesamo.jpg" alt="" width="1920" height="1280" srcset="https://cesamo.fr/wp-content/uploads/2020/10/qexative-thermo-spectrometrie-de-masse-cesamo.jpg 1920w, https://cesamo.fr/wp-content/uploads/2020/10/qexative-thermo-spectrometrie-de-masse-cesamo-300x200.jpg 300w, https://cesamo.fr/wp-content/uploads/2020/10/qexative-thermo-spectrometrie-de-masse-cesamo-1024x683.jpg 1024w, https://cesamo.fr/wp-content/uploads/2020/10/qexative-thermo-spectrometrie-de-masse-cesamo-768x512.jpg 768w, https://cesamo.fr/wp-content/uploads/2020/10/qexative-thermo-spectrometrie-de-masse-cesamo-1536x1024.jpg 1536w, https://cesamo.fr/wp-content/uploads/2020/10/qexative-thermo-spectrometrie-de-masse-cesamo-700x467.jpg 700w" sizes="(max-width: 1920px) 100vw, 1920px" /></p>
<h3 style="text-align: justify;"></h3>
<p>Location : 2<sup>nd</sup> floor  East, room 2N24</p>
<p style="text-align: justify;">It is an orbitrap-type mass spectrometer that was acquired in 2018. It has a resolving power of 140,000 FWHM (Full Width at Half Maximum). The range of masses that can be analyzed with this type of device extends from 50 to 6000 m/z. The precision of the mass measurement is less than 1 ppm in internal calibration and less than 3 ppm in external calibration. This instrument is equipped with an ESI (Electrospray) ionization source. This instrument is used in conjunction with Vanquish liquid chromatography.</p>
<p>This instrument is used :</p>
<ul>
<li style="text-align: justify;">for mass measurements in high resolution (determination of molecular formulas) on pure or mixed products (LC / MS coupling in high resolution).</li>
<li style="text-align: justify;">For specific studies relating to the MS/MS mode.</li>
</ul>
<p style="text-align: justify;">
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/qexactive-thermo-en/">Qexactive &#8211; Thermo</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Bruker AVANCE III 600 MHz</title>
		<link>https://cesamo.fr/en/portfolio_page/bruker-avance-iii-600-mhz-en/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=bruker-avance-iii-600-mhz-en</link>
		
		<dc:creator><![CDATA[Marguerite]]></dc:creator>
		<pubDate>Tue, 13 Oct 2020 08:08:38 +0000</pubDate>
				<guid isPermaLink="false">http://cesamo.fr/?post_type=portfolio_page&#038;p=406</guid>

					<description><![CDATA[<p>Bruker AVANCE III 600 MHz &#160; For liquid-and gel-state NMR applications Probes : Inverse 5 mm BBI type (1H/15N-31P/2H) with Z-gradients and ATM for liquid-state NMR analysis Inverse 4 mm double resonance 1H/13C with Z-gradients for high resolution gel-state NMR analysis Console and accessories: Avance III,...</p>
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/bruker-avance-iii-600-mhz-en/">Bruker AVANCE III 600 MHz</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 style="text-align: justify;"></h3>
<h3 style="text-align: justify;">Bruker AVANCE III 600 MHz</h3>
<p style="text-align: justify;"><img loading="lazy" decoding="async" class="alignnone wp-image-233 size-full" src="http://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-avance-neo-600-mhz.jpg" alt="" width="1920" height="1280" srcset="https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-avance-neo-600-mhz.jpg 1920w, https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-avance-neo-600-mhz-300x200.jpg 300w, https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-avance-neo-600-mhz-1024x683.jpg 1024w, https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-avance-neo-600-mhz-768x512.jpg 768w, https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-avance-neo-600-mhz-1536x1024.jpg 1536w, https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-avance-neo-600-mhz-700x467.jpg 700w" sizes="(max-width: 1920px) 100vw, 1920px" /></p>
<p>&nbsp;</p>
<p>For liquid-and gel-state NMR applications</p>
<p><em>Probes</em> :</p>
<ul>
<li>Inverse 5 mm BBI type (<sup>1</sup>H/<sup>15</sup>N-<sup>31</sup>P/<sup>2</sup>H) with Z-gradients and ATM for liquid-state NMR analysis</li>
<li>Inverse 4 mm double resonance <sup>1</sup>H/<sup>13</sup>C with Z-gradients for high resolution gel-state NMR analysis</li>
</ul>
<p><em>Console and accessories</em>: Avance III, BCU 05 temperature range between -70 °C and +110 °C</p>
<p><em>Workstation</em>: Topspin 3.6.2</p>
<p>It is available for ISM researchers and for all the scientific community on demand and prior booking alongside service staff (see contacts).</p>
<p>We carry out 1D and 2D (homo and heteronuclear) measures, kinetic studies like EXSY, calculation of compounds diffusion coefficient with DOSY experiment, quantitative analysis, temperature variations (from -70 °C to +110 °C), NMR of gels (<sup>1</sup>H and <sup>13</sup>C) …</p>
<p style="text-align: justify;">
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/bruker-avance-iii-600-mhz-en/">Bruker AVANCE III 600 MHz</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Bruker AVANCE II 400 MHz</title>
		<link>https://cesamo.fr/en/portfolio_page/bruker-avance-ii-400-mhz-en/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=bruker-avance-ii-400-mhz-en</link>
		
		<dc:creator><![CDATA[Marguerite]]></dc:creator>
		<pubDate>Tue, 13 Oct 2020 07:54:46 +0000</pubDate>
				<guid isPermaLink="false">http://cesamo.fr/?post_type=portfolio_page&#038;p=405</guid>

					<description><![CDATA[<p>Bruker AVANCE II 400 MHz For liquid and solid-state NMR applications   Probes : Direct 5 mm BBFO type (1H/15N-31P/2H) with Z-gradients and ATM for liquid-state NMR analysis Inverse 4 mm double resonance 1H/13C with Z-gradients for powders analysis Console and accessories: Avance II, BCU 05...</p>
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/bruker-avance-ii-400-mhz-en/">Bruker AVANCE II 400 MHz</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 style="text-align: justify;"></h3>
<h3 style="text-align: justify;">Bruker AVANCE II 400 MHz</h3>
<p style="text-align: justify;"><img loading="lazy" decoding="async" class="alignnone wp-image-100 size-full" src="http://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-plateforme-analyse-bordeaux.jpg" alt="" width="1920" height="1280" srcset="https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-plateforme-analyse-bordeaux.jpg 1920w, https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-plateforme-analyse-bordeaux-300x200.jpg 300w, https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-plateforme-analyse-bordeaux-1024x683.jpg 1024w, https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-plateforme-analyse-bordeaux-768x512.jpg 768w, https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-plateforme-analyse-bordeaux-1536x1024.jpg 1536w, https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-plateforme-analyse-bordeaux-700x467.jpg 700w" sizes="(max-width: 1920px) 100vw, 1920px" /></p>
<h3 style="text-align: justify;"></h3>
<p>For liquid and solid-state NMR applications</p>
<p><em> </em></p>
<p><em>Probes</em> :</p>
<ul>
<li>Direct 5 mm BBFO type (<sup>1</sup>H/<sup>15</sup>N-<sup>31</sup>P/<sup>2</sup>H) with Z-gradients and ATM for liquid-state NMR analysis</li>
<li>Inverse 4 mm double resonance <sup>1</sup>H/<sup>13</sup>C with Z-gradients for powders analysis</li>
</ul>
<p><em>Console and accessories</em>: Avance II, BCU 05 temperature range between -70 °C and        +110 °C</p>
<p><em>Workstation</em>: Topspin 3.2</p>
<p>It is available for ISM researchers and for all the scientific community on demand and prior booking alongside service staff (see contacts).</p>
<p>We conduct 1D and 2D multi-nucleus measures, temperature variations (from -70 °C to       +110 °C), NMR of solids …</p>
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/bruker-avance-ii-400-mhz-en/">Bruker AVANCE II 400 MHz</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Bruker AVANCE III 300 MHz</title>
		<link>https://cesamo.fr/en/portfolio_page/bruker-avance-iii-300-mhz-en/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=bruker-avance-iii-300-mhz-en</link>
		
		<dc:creator><![CDATA[Marguerite]]></dc:creator>
		<pubDate>Tue, 13 Oct 2020 07:42:31 +0000</pubDate>
				<guid isPermaLink="false">http://cesamo.fr/?post_type=portfolio_page&#038;p=404</guid>

					<description><![CDATA[<p>Bruker AVANCE III 300 MHz For liquid-state NMR applications Direct probe BBFO type (1H/15N-31P/2H), X-channel is accordable on 19F with Z-gradients and ATM Console and accessories: Avance III nanobay, 60 positions sample changer (BACS-60)   Workstation: Topspin 3.6.2 Its utilization is fully automatic, short 1D...</p>
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/bruker-avance-iii-300-mhz-en/">Bruker AVANCE III 300 MHz</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 style="text-align: justify;"></h3>
<h3 style="text-align: justify;">Bruker AVANCE III 300 MHz</h3>
<p style="text-align: justify;"><img loading="lazy" decoding="async" class="alignnone wp-image-232 size-full" src="http://cesamo.fr/wp-content/uploads/2020/10/rmn-cesamo-equipement-bordeaux.jpg" alt="" width="1920" height="1280" srcset="https://cesamo.fr/wp-content/uploads/2020/10/rmn-cesamo-equipement-bordeaux.jpg 1920w, https://cesamo.fr/wp-content/uploads/2020/10/rmn-cesamo-equipement-bordeaux-300x200.jpg 300w, https://cesamo.fr/wp-content/uploads/2020/10/rmn-cesamo-equipement-bordeaux-1024x683.jpg 1024w, https://cesamo.fr/wp-content/uploads/2020/10/rmn-cesamo-equipement-bordeaux-768x512.jpg 768w, https://cesamo.fr/wp-content/uploads/2020/10/rmn-cesamo-equipement-bordeaux-1536x1024.jpg 1536w, https://cesamo.fr/wp-content/uploads/2020/10/rmn-cesamo-equipement-bordeaux-700x467.jpg 700w" sizes="(max-width: 1920px) 100vw, 1920px" /></p>
<p>For liquid-state NMR applications</p>
<p><em>Direct probe</em> BBFO type (<sup>1</sup>H/<sup>15</sup>N-<sup>31</sup>P/<sup>2</sup>H), X-channel is accordable on <sup>19</sup>F with Z-gradients and ATM</p>
<p><em>Console and accessories</em>: Avance III nanobay, 60 positions sample changer</p>
<p>(BACS-60)</p>
<p><em> </em></p>
<p><em>Workstation</em>: Topspin 3.6.2</p>
<p>Its utilization is fully automatic, short 1D NMR experiments during the day and long 1D, 2D studies during the night and week-end. After formation, this spectrometer is available, in free-access for the Institute researchers.</p>
<p style="text-align: justify;">
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/bruker-avance-iii-300-mhz-en/">Bruker AVANCE III 300 MHz</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Bruker AVANCE NEO 300 MHz</title>
		<link>https://cesamo.fr/en/portfolio_page/bruker-avance-neo-300-mhz-en/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=bruker-avance-neo-300-mhz-en</link>
		
		<dc:creator><![CDATA[Marguerite]]></dc:creator>
		<pubDate>Tue, 13 Oct 2020 07:34:43 +0000</pubDate>
				<guid isPermaLink="false">http://cesamo.fr/?post_type=portfolio_page&#038;p=403</guid>

					<description><![CDATA[<p>&#160; Bruker AVANCE NEO 300 MHz for liquid-state NMR applications Probes : Direct 5 mm BBFO type (1H/15N-31P/2H), X-channel is accordable on 19F with Z-gradients and ATM Inverse 5 mm BBI (1H/15N-31P/2H) with Z-gradients and ATM Console and accessories: Avance NEO, 60 positions sample changer (Sample...</p>
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/bruker-avance-neo-300-mhz-en/">Bruker AVANCE NEO 300 MHz</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<h3 style="text-align: justify;"></h3>
<h3 style="text-align: justify;">Bruker AVANCE NEO 300 MHz</h3>
<p style="text-align: justify;"><img loading="lazy" decoding="async" class="alignnone wp-image-99 size-full" src="http://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-avance-neo-300-mhz.jpg" alt="" width="1920" height="1280" srcset="https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-avance-neo-300-mhz.jpg 1920w, https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-avance-neo-300-mhz-300x200.jpg 300w, https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-avance-neo-300-mhz-1024x683.jpg 1024w, https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-avance-neo-300-mhz-768x512.jpg 768w, https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-avance-neo-300-mhz-1536x1024.jpg 1536w, https://cesamo.fr/wp-content/uploads/2020/10/resonnance-magnetique-nucleaire-equipement-bruker-avance-neo-300-mhz-700x467.jpg 700w" sizes="(max-width: 1920px) 100vw, 1920px" /></p>
<h3 style="text-align: justify;"></h3>
<ul>
<li>for liquid-state NMR applications</li>
</ul>
<p><em>Probes</em> :</p>
<ul>
<li>Direct 5 mm BBFO type (<sup>1</sup>H/<sup>15</sup>N-<sup>31</sup>P/<sup>2</sup>H), X-channel is accordable on <sup>19</sup>F with Z-gradients and ATM</li>
<li>Inverse 5 mm BBI (<sup>1</sup>H/<sup>15</sup>N-<sup>31</sup>P/<sup>2</sup>H) with Z-gradients and ATM</li>
</ul>
<p><em>Console and accessories</em>: Avance NEO, 60 positions sample changer (Sample Case)</p>
<p><em> Workstation:</em> Topspin 4.0.9</p>
<p>Its utilization is fully automatic, short 1D NMR experiments during the day and long 1D, 2D studies during the night and week-end. After formation, this spectrometer is available, in free-access for the Institute researchers.</p>
<p style="text-align: justify;">
<p>L’article <a href="https://cesamo.fr/en/portfolio_page/bruker-avance-neo-300-mhz-en/">Bruker AVANCE NEO 300 MHz</a> est apparu en premier sur <a href="https://cesamo.fr/en/home">Cesamo</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/?utm_source=w3tc&utm_medium=footer_comment&utm_campaign=free_plugin


Served from: cesamo.fr @ 2026-05-31 15:55:46 by W3 Total Cache
-->